EN 14511-2 PDF

BS EN Air conditioners, liquid chilling packages and heat pumps for space heating and cooling and process chillers, with. Find the most up-to-date version of EN at Engineering NBN EN Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling – Part 2: Test.

Author: Dajas Zulugar
Country: Algeria
Language: English (Spanish)
Genre: Personal Growth
Published (Last): 10 November 2014
Pages: 328
PDF File Size: 7.60 Mb
ePub File Size: 8.92 Mb
ISBN: 698-4-65347-259-2
Downloads: 73332
Price: Free* [*Free Regsitration Required]
Uploader: Nak

Currently the P-marking rules are being revised to bring them into line with new European requirements and standard EN The loudness of the noise depends on the size of the room in which the heat pump is installed, its shape and its attenuation echo.

The performance rating shall be established in accordance with the test procedure of EN SP is accredited to perform tests in accordance with standard ENwhich contains calculation methods for determination of seasonal energy efficiency and seasonal coefficient of performance.

NOTE 1 For air-to-water, brine-to-water and water-to-water units, the manufacturer may declare the water temperatures levels lower, medium, high and very high applicable to the heating mode.

NBN EN 14511-2

SP Method is a method under progress used to calculate the seasonal performance factor of a system and the annual energy savings of air-to-water heat pumps. Test conditions This document has been re-assessed by the committee, and judged to still be up to date. The method is based on the calculation method in standard EN The standard also describes testing with reduced capacity in heating operation mode or cooling operation mode.

Standard rating conditions indicated in Table 20 shall be used to determine the cooling capacity, the EER, the annual energy consumption and the efficiency class of air-cooled multisplit air conditioners.

  HACIENDOSE ESCRITOR DOROTHEA BRANDE PDF

Performance of electrical appliances – Airconditioners and heat pumps – Water-source heat pumps – Water-to-air and brine-to-air heat pumps – Testing and rating of performance You may be interested in this related standard Air-handling and water systems of buildings – Microbial control – Part 4: Get a quote for certification of systems, products or services, and get certified.

EVS-EN – Estonian Centre for Standardisation

SP is accredited to perform tests in accordance with SP Method that the method of performance-testing of electrically driven exhaust air heat pumps, determining their thermal power capacity, hot water production capacity and ventilation performance. SP is accredited enn perform field measurement tests in accordance with SP Method which is a method for measurement of the capacity and electricity consumption of air-to-air heat pumps in the field.

The sound power level is a measure of the contribution of noise to the surroundings caused by the heat pump. Please download Chrome or Firefox or view our browser tips. The test involves two draw offs of half the volume of the storage tank, together with a single tapping to determine the maximum quantity of useable hot water and the reference hot water temperature.

EN Test conditions_百度文库

The marking also includes heat pumps intended for pool heating. The data used in the calculations are based on results from a number of test points derived 145112 capacity and efficiency testing in accordance with ENEN and EN and some additional test point. SP Method updated version.

SP Method is a method used to calculate the seasonal performance factor of a system and the annual energy savings of water-to-water heat pumps and brine-to-water heat pumps. SP Method calculation of annual energy savings. Affiliation List of ICS codes. Terms and definitions, Part 2: For reverse cycle units, the heating capacity and the efficiency class shall be determined from one of the standard rating conditions indicated in Table 3 depending of the heat source and heat sink.

  BUKU THE CASHFLOW QUADRANT PDF

For reverse cycle air-cooled multisplit units, the heating capacity and the efficiency class shall be determined from the standard rating conditions indicated in Table The standard does not include test on electrical safety, mechanical safety, control equipment and sound power level.

Testing and requirements for marking for space heating units Withdrawn. Beaulier Date of publication: Code s Theme s The data from the test are used to calculate the system seasonal performance factor. The houses are postulated as located in rn with average annual temperatures of 8.

EN comprises the following parts under the general title Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling: The method specifies the testing procedure, depending on whether the heat pump has constant capacity, variable capacity or incremental capacity control. Fite Date of publication: Air-to-water, water-to-water and direct-expansion heat pumps can be tested and inspected for approval under this scheme.

This standard describes the testing procedure for direct-expansion ground-coupled heat pumps. We use cookies to make our website easier to use and to better understand your needs. Testing includes performance, security, sound level and electrical characteristics, together with inspection of technical data, maintenance and installation instructions. Terms and definitions EN Register online at inter and intra-company training, and certifying diplomas, seminars, distance learning.